Dokumentin teksti
Centrifugal Fans Main Catalogue 2019 General notes Explanation of technical details Dynamic pressure p d2 = k d2 ZAbluefinECblue Air flow in m3/h k-factors for calculation of the dynamic pressure ZAbluefin Size kd2 25I.CR 31I.CR 28I.CR 35I.CR 40I.CR 45I.CR 50I.CR C Size kd2 5.59 · 10-6 25C.CR 9.66 · 10-6 2.22 · 10 31C.CR 4.01 · 10 3.56 · 10-6 -6 1.39 · 10-6 8.62 · 10-7 5.39 · 10-7 3.54 · 10-7 2.25 · 10-7 28C.CR 35C.CR 40C.CR 45C.CR 50C.CR 56C.CR 63C.CR Size 6.26 · 10-6 -6 2.53 · 10-6 1.61 · 10-6 1.00 · 10-6 6.22 · 10-7 4.06 · 10-7 2.58 · 10-7 ZAvblue kd2 kd2 1.14 · 10-5 25V.VR 1.29 · 10-5 4.78 · 10 31V.VR 5.12 · 10 22C.1R 1.85 · 10-5 28C.1R 7.44 · 10-6 25C.1R 31C.1R 35C.1R 40C.1R 45C.1R 50C.1R 56C.1R -6 2.96 · 10-6 1.82 · 10-6 1.13 · 10-6 7,14 · 10-7 4.65 · 10-7 63C.1R 2.98 · 10-7 80C.1R 1.15 · 10-7 71C.1R Vpro Size 1.86 · 10-7 28V.VR 35V.VR 40V.VR 45V.VR 50V.VR 56V.VR 63V.VR 8.27 · 10-6 -6 3.29 · 10-6 1.87 · 10-6 1.22 · 10-6 8.12 · 10-7 5.27 · 10-7 3.45 · 10-7 Size kd2 28V.1R 8,60 · 10-6 31V.1R 35V.1R 40V.1R 45V.1R 50V.1R 56V.1R 63V.1R 5.32 · 10-6 3.37 · 10-6 2.13 · 10-6 1.36 · 10-6 8.82 · 10-7 5.37 · 10-7 3.36 · 10-7 Vpro-ECblue 56I.CR Cpro/ZAcube Cpro-ECblue qv Dynamic pressure at fan outlet in Pa Constant factor for calculation of the dynamic pressure C-ECblue kd2 2 ZAvblue pfd2 v Information Calculation of the dynamic pressure: ZAcubeCpro-ECblue Example: RH28C.CR 75 RH31C.CR 95 RH35C.CR 121 RH40C.CR 154 RH45C.CR 197 RH50C.CR 252 RH56C.CR 308 RH63C.CR 381 pd2 = 197 · qv2 System components 60 Control technology Constant RH25C.CR General notes Size Housing fans Type RH45C-ZID.GG.CR, article no. 114613 ziehl-abegg.com 353 General notes Aerodynamics and acoustics Centrifugal Fans Main Catalogue 2019 Aerodynamics and acoustics Measurement method fs in Pa as a funktion of the air flow rate qV1 in m3/h. Technical conditions of supply The specified performance data meet the respective requirements for accuracy AN2 for impellers without motor AN3 for fans with standard motors AN2 for impellers with ECblue motors (except EC055) AN3 for impellers with EC motor EC055 (see type key) AN4 for fans with AC external rotor motors in line with ISO 13348 and apply to the rated data and air performance curves at the rated voltage. The continuous line in the characteristic curve represents the optimum reliable operating range for fans. Fan test bench The fan characteristic curves are determined on a combined air performance and acoustic test bench. The fan characteristic curves are measured in compliance to DIN EN ISO 5801, respectively AMCA 210-99. The sound power levels are measured in compliance with DIN EN ISO 3745 and ISO 13347-3 using the enveloping surface measuring method. The figure below shows an example of the measuring setup. The fan intake is installed in the measuring chamber at free inlet and free exhaust (installation type A as per DIN EN ISO 5801 respectively AMCA 210-99). Air density The air temperature and humidity are conditioned during the measurement using heat exchangers and kept largely constant. The characteristic curves shown refer to the measuring density. The mean measuring density is 1.16 kg/m³. p p p p fs 354 ziehl-abegg.com General notes Installation and usage information Centrifugal Fans Main Catalogue 2019 Installation and usage information Measuring device for determining air volume The active pressure process compares the static pressure before the inlet nozzle with the static pressure in the inlet nozzle at the place of greatest constriction (lowest free nozzle cross sectional area). Using the energy conservation principle, the active pressure (differential pressure of the static pressures) can be assigned to the air flow as follows: Under normal conditions at 20°C: Under fluctuating air conditions: qV qV= 20 Betr · k20 · w Air flow in m3/h Coefficient for specific nozzle properties, nozzle factor Standard air density with 1.2 kg/m3 Nozzle coefficients Size ZAbluefin Standard k 175 With guard grille kg Cpro Standard k C With guard grille kg ZAvblue Standard k With guard grille kg Standard k 190 220 250 67 63 315 106 100 95 91 180 170 154 148 280 355 400 450 500 560 630 85 80 140 130 220 210 280 265 355 335 710 60 75 121 197 252 308 381 58 47 46 75 72 60 72 95 Standard k Standard k Standard k 38 38 38 38 308 365 381 490 Example: If an active pressure of 700 Pa is measured for size GR63I, the air flow can be calculated as follows, using this simplified formula: 3 /h The corresponding active pressure / air flow characteristic curves can be downloaded from our website in the Download section under Product Information. The nozzle coefficients (k factors) were determined under laboratory conditions and with an undisturbed supply. If inlet guard grilles are used (fitted in front of the inlet nozzle), these nozzle factors cannot be used for air flow determination because of a change in the supply flow and other static pressures. 71 90 50 63 86 200 180 189 295 95 112 71 148 197 252 80 75 112 189 242 71 38 120 116 154 p = 1.20 kg/m³ 364 Vpro 91 121 620 w 58 116 800 qv ZApilot 38 200 225 ZAvblue with EC055 242 295 365 470 150 240 320 400 480 144 220 291 360 445 594 Notes pertaining to the measuring method The measured values, which were determined using the active pressure method, are subject to a tolerance of +/- 8.0% as they pertain to the airflow result. This tolerance is reached above a minimum air velocity of approx. 29.53 ft/s at the place of greatest constriction. The tolerances cannot be clearly quantified below this minimum air velocity. This air flow measuring method is only suitable for acceptance measurements on site. For a more accurate air flow determination in the existing installation setup, a counter calibration of the air flow has to be carried out on site to measure the active pressure. The nozzle factors determined during this process apply exclusively to this installation setup. ziehl-abegg.com L-KL-2995-2 Air density at current operating point in kg/m3 Pw S Differential pressure of the static pressures in Pa Pw w k w L-KL-2995-4 qv .